drag to orbit · scroll to zoom · right-drag to pan
Earthquake city block · 7 buildings, 3–60 st.
Earthquake PGA –
Tuned mass damper 60-story
OFF
– cmON
– cm
Peak roof displacement, same shaking.
Playback 0.0 / 0 s
View
Ground acceleration 0.00 g
Response spectrum · 5% damped Sa (g)
60-story roof displacement 0 cm
Buildings drift = peak story drift
building
st.
T₁ s
drift %
roof cm
state
Bar = peak drift ÷ 2.5%. Click a row to fly to the building.
Damper cam · rides with the roof
lockedstroke 0 cm
Loading…
Simplified model: lumped-mass shear buildings · modal damping · one horizontal component · displacements drawn ×8 · all assumptions
Assumptions of the simplified structural model
Ground motion. A synthetic accelerogram is generated in the browser with the stochastic point-source method: windowed Gaussian noise shaped to a Brune ω² source spectrum (100 bar stress drop), 1/R spreading with anelastic attenuation, generic crustal/site amplification and, for the basin site, a narrow-band long-period wave train near 0.18 Hz. It has one horizontal component acting along the street, is identical under every foundation (no wave passage, no soil–structure interaction, no vertical or rocking motion), and is fixed by its seed so every replay uses exactly the same shaking. PGA and spectra are indicative, not design values.
Buildings. Each building is a planar lumped-mass shear building: one lateral degree of freedom per floor, rigid floor plates, story stiffness tapering with height and scaled so the fundamental period equals the listed T₁ (roughly 0.1 s per story, adjusted for the structural system). Response is linear-elastic modal superposition (up to 6 modes) with constant modal damping of 1.2–5%. No torsion, no P-Δ, no pounding and no foundation flexibility. The table flags peak story drift as minor (≥0.5%), damage (≥1%) or severe (≥2%); linear results above about 2% are only indicative because a real structure would be yielding.
Soft story. The ground story of the 7-story apartment block has 22% of the stiffness of the story above. It is elastic–plastic (yield at a base shear of 0.11 W), loses strength as its largest drift grows beyond 0.8%, and includes P-Δ. When the ground-story drift exceeds its capacity of 2.5% the columns are taken to have lost their lateral and most of their axial strength: the stories above then drop as one rigid block under gravity, carrying the velocity they had at that instant. Collapse time and direction therefore come from the computed response, not from a script.
Tuned mass damper. A single pendulum mass at the roof of the 60-story tower: 5% of the first-mode generalised mass (about 1,800 t, 2% of the building), linear spring and viscous dashpot tuned with Warburton’s formulas for base excitation (frequency ratio 0.94) with the damping raised to 15% to limit stroke. Stroke is unlimited and there are no bumpers. “OFF” means the mass is locked to the structure.
What you see. Ground and building displacements are magnified by the “Magnify” factor so they are visible at city scale; the damper stroke and the collapse drop are drawn at true scale. Time runs at real speed unless changed.